Frigo Plus Maxiline

MAXILINE

Industrial, big capacity chillers

  • Number of screw compressors: 1 or 2
  • Compressor type CXH02, CXH52, CXH92
  • Condensers configuration: P4, P6, P8, P10, P12, P14, P16

Options:

  • Primary pump
  • Heat recovery
  • Desuperheater
  • Natural refrigerant
  • Compact screw compressors
  • Inverter driven compressors
  • High efficiency asymmetric evaporators
  • Microchannel aluminum air condenser
  • EC air condenser fans for precise condensing control
  • Electronic expansion valve
  • Innovative technical cooling solution for high energy efficiency

AIR COOLED CHILLERS


MAXILINE air cooled chillers  are  used  for  indirect  cooling  for of industrial  processes,  milk proccesing industry, chemical industry, logistics  centers and for  food retail. Heat transfer fluid can be water, mixture of water and ethylene/propylene glycol or some other secondary heat transfer fluid.

Air-water  chiller  is  packaged  in  a  single  housing  and  all  the  components  of  the refrigerant circuit are built into the unit. Thus, chillers is compact and easy to install on the site. Refrigerant is propane (R290), which due to its excellent thermodynamic properties allows the use of the chiller in the temperature range from -35 to 20 °C. A microprocessor controls the operation of the unit and optimized parameters in order to achieve as high efficiency as possible.

HOUSING


  • Housing made of powder-coated galvanized sheet metal
  • Screws, nuts and rivets made of stainless steel
  • Guard grille at the outlet from the axial fan
  • Panels on compressor and hydraulic space with locks

ELECTRICAL PART


  • Emergency stop mushroom pushbutton with CES key
  • Phase failure monitoring reley
  • Electrical cables labeling in the unit according to the electrical scheme
  • Electrical cables for outdoor installation UV resistant
  • Time relay for automatic reset of chiller in case of power failure
  • Main switch on the electrical cabinet
  • Cable clamp rail for power supply cable
  • Control transformer 230/230 V and transformer housing earthing

REFRIGERATION CIRCUIT COMPONENTS


  • Compressor with 2 rotalock valves, oil crankshaft heater, oil control glass
  • Motor windings thermally protection and electronic module
  • HP pressure switch is connected to the compressor before the rotalock valve
  • Service ball valve before filter drier, filter drier and sight glass
  • Service Schrader valve on LP and HP side
  • Economizer for efficiency increase of the refrigeration circuit
  • Thermal insulation of the refrigeration circuit low pressure side
  • Safety valve on HP and LP side
  • Electronic expansion valve with safety function of excessively high evaporation pressure

HYDRAULIC CIRCUIT COMPONENTS


  • Pipes up to 2” made of copper and flare connection, above DN 50 made of stainless steel and flange connection
  • Pipe connections outside of the housing for easier connection to the system
  • Automatic air vent valve mounted on the closing valve
  • Drain valves on lowest positions
  • Safety valve 6 or 10 bar
  • Standard thermal insulation of 19 mm
  • Optional Y-strainer installed on the inlet pipe
  • Optional AC/EC Primary pump
  • Optional Buffer tank
  • Manometer 0 – 10 bar (standard equipment with pump or buffer)
  • Optional serial heat recovery or desuperheater in configurations

SAFETY


All chillers are designed in accordance with the highest safety standards and follows NORM EN378 for refrigerants from group A3.

ECOLOGY


Natural refrigerant: propane – R290.

It belongs to the group of hydrocarbons with GWP = 3 which is completely

exempted from the restrictions prescribed by the EU F-gas directive.

ENERGY EFFICENCY


Thanks to the ideal thermodynamic characteristics of the R290 refrigerant, and the optimal selection of the key components of the refrigeration circuit, the chillers have high energy efficiency and meet the requirements of ECODESIGN REGULATIONS.

QUALITY PROGRAM


  • Testing units according to  HRN EN 14511
  • ISO 9001:2015
  • Modul A2 – Monitoring of Final Assessment according to directive 2014/68/EU

Cooling Temperature Regimes

HT +2°C…..+20°C
MT -15°C…..+2°C
LT -35°C…..-15°C

Cooling Capacity

120kW…..850kW*

* external air temperature 35°C, evaporator inlet/outlet water, 12/7 °C

SIEMENS CONTROLLER

  • Intuitive and user frendly touchscreen
  • Innovative algorithm for precise control of outlet water/glycol
  • Advanced operation control for „heat recovery” and precise outlet hot water temperature
  • Alarm managment for safe and reliable chiller operation
  • Easy connectivity with standard MODBUS and BacNET protocols

Optional equipment

  • AC/EC Primary pump
  • Serial heat recovery
  • Desuperheater
  • Integrated free cooling

*not possible with largest compressors